Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of:±([% of Reading] + [Number of Least Significant Digits])


Accuracy Specifications
Function Range Resolution Accuracy
AC Volts
(40 Hz to 500Hz)1
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode Test2 2.000 V 0.001 V 10 %
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA
Duty Cycle4 1 % to 99 % 0.1 % NA
AC Current
(40 Hz to 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 600 V 1 >10 MΩ <100 pF 2 >60 dB at dc,
50 Hz or 60 Hz
\AC Millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 600 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery Type 2 AAA, NEDA 24A, IEC LR03
Battery Life 200 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs 11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL) 142 mm x 69 mm x 28mm
Weight 200 g
IP Rating IEC 60529:IP 40
Safety IEC 61010-1:600 V CAT III, Pollution Degree 2
Electromagnetic Environment IEC 61326-1:Portable
Electromagnetic Compatibility Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1
  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

Manuals

Register products

Shipping Policies:

  1. To Ensure that your order reaches you in the fastest time and in good condition, we only ship our goods through SHIPROCKET, DTDC and SPEEDPOST
  2. We currently do not have an option for the customer to choose a delivery partner, Our logistics team will use the best possible shipping method to execute the order.
  3. Our Team strives to ship all items in your order together but this might not be possible at all times due to the properties or availability of the products either case we inform the customer before proceeding with the shipment.

Damage in Transit:

  1. If you find that the packing of package delivered is tampered or damaged and that it might have caused damage to the product inside before accepting the shipment, you must click a picture and refuse to accept the delivery and inform our Customer Care +91 8606650999 along with your order number. We will make our best efforts to ensure replacement delivery at the earliest.

Order Tracking:

You may track the order through the fulfilment emails send from our email: help@tomsonelectronics.com or through the SMS sent from SHIPROCKET to your registered mobile number at the time of placing order

Shipping Time & Delivery:

  1. Orders Placed up to 4:00PM will be packed and prepared to be shipped on the same day.
  2. We make our best efforts to prepare the orders for shipping on the same day or within 24 hours from the time the order was received.
  3. Due to the pandemic the government has imposed a restriction on the functioning of delivery partners hence a slight delay can be expected in transferring the packages to the concerned delivery partners.
  4. Our logistics partners guarantee a delivery of packages within 1-6 Working days to anywhere in India there can be delays as each shipping partner has their own method and transit hubs to each location hence the exact delivery time is not predictable therefore we request all our customers plan your orders allowing sufficient time for the delivery.

Making changes in order:

For making changes in order, you can contact us via email or call within 2 hours from the time of placing order for making changes in following fields

  1. Product
  2. Quantity
  3. Address